Sophisticated Analytical Instrument Facility (SAIF), was established at the Karnatak University, Dharwad in 2014 with the financial support from the Department of Science and Technology (DST), Government of India, with the following objectives:
SAIF centre houses the following instruments:
The facilities provided by the SAIF may be utilized by any user/organization on payment of nominal charges. The details about the procedure for the submission of the samples and the charges for sample analysis can be obtained from the University website (www.kud.ac.in) or from SAIF centre, Karnatak University, Dharwad. Online registration and online payment is mandatory.
The day-to-day functioning of the SAIF is overseen by Prof. J Seetharamappa Head, SAIF. The Facilities Management Committee (FMC) oversees and guides the activities of the SAIF.
For DST‐SAIF facilities: Account holder: SAIF KUD USER CHARGES ACCOUNT,SB A/c No. 12062010023433, Canara Bank; Karnatak University Campus, Dharwad. (IFSC:CNRB0011206).
Auto Tune Probe: With auto tuning unit, automatically tuning is done for multiple nuclei
Observations Nuclei: 1H, 13C, 19F, 31P to 15N, 39K and 109Ag
Type of Experiments: 1D and 2D NMR spectra of all active nuclei, DEPT, APT, Cosy, Cosy with or without gradient, TOCSY,NOESY, HMQC and HMBC
Resolution: High vacuum mode: 3.0 nm (30 kV) 15.0 nm (1.0 kV) Low vacuum mode: 4.0 nm (30 kV BED)
Accelerating Voltage: From 0.3KV-30KV in 1KV step
Magnification: 8X (WD 48mm) to 300000X
Detector: Secondary Electron Detector (SED), Backscattered Electron Detector (BED), Low Vacuum Secondary Electron Detector (LSED), Energy Dispersive X-ray Spectrometer (EDS)
Accessories: Critical point drier, Ion sputter system, Carbon coating unit
Fully automated alignment under computer control
SAXS capabilities
Optional D/teXUltra high-speed, position-sensitive detector system
2Θ: 2° to 150°
Xenon arc lamp source
Two quartz cell path lengths, 1mm and 1cm possible
Temperature ramping (-40o to 130oC) and thermal denaturation for screening binding
Wide spectral range from vacuum UV to Near-IR (163 to 1600 nm)
Sl No. | Instrument | Measurement | Charges per sample in Rs. | ||
---|---|---|---|---|---|
Internal User(KUD Students) | External Users (Students from other Colleges / Institutions/Universities) | Private Industry / Research Organizations / National Labs / PSU | |||
1 | SEM with EDS (JEOL make, JSM-IT500LA) Staff in charge: Mr. Raju Shivalli, 8217289503 E-mail:sem.saifkud@gmail.com |
SEM Imaging | 250/- | 500/- +18% GST | 700/- +18% GST |
EDS | 150/- | 300/- +18% GST | 400/- +18% GST | ||
Mapping | 200/- | 350/- +18% GST | 500/- +18% GST | ||
2 |
Powder X-ray Diffractometer (Smart lab SE) Staff in charge: Mr. Akash Badami, 8050122306, Email:akashcool388@gmail.com |
XRD | 300/- | 500/- +18% GST | 700/- +18% GST |
Phase Identification | 150/- | 300/- +18% GST | 400/- +18% GST | ||
3 | 400 MHz FT-NMR (JEOL make JNM-ECZ400S) Staff in charge: Mr. Pavan Bennur, 7795979950 Email:111994benz@gmail.com |
Proton | 250/- | 300/- +18% GST | 500/- +18% GST |
Proton & Carbon spectra | 400/- | 500/- +18% GST | 1000/- +18% GST | ||
4 | CD Spectrometer (Jasco J-1500) Staff in charge: Mr. Pavan Bennur, 7795979950 Email:111994benz@gmail.com |
Circular Dichroism | 50 Per Sample (Up to 5 scans) | 100/- +18% GST Per Sample (Up to 5 scans) | 300/- +18% GST Per Sample (Up to 5 scans) |
5 | Liquid Nitrogen Plant (LN40WC) Staff in charge: Mr. Pavan Bennur, 7795979950 Email:111994benz@gmail.com |
30/- Per Ltr | 50/- Per Ltr | 75/- Per Ltr |
Sl.No. | Instrument | Make/Model | Major Specifications / Accessories available | Type of measurement / Analysis available |
---|---|---|---|---|
1 | FT-NMR Spectrometer | Jeol 400 MHz / JNM- ECZ 400S | Operating Frequency:400 MHz Probe,-800C to 1500C temperature Auto sample changer with handling capacity of 30 samples | Structure identification of organic, inorganic and polymer materials 1D and 2D NMR spectra of all active nuclei, DEPT, APT, Cosy,Cosy with or without gradient, TOCSY, NOESY, HMQC, HMBC etc. |
2 | X-ray Diffractometer (Powder) | Rigaku Smartlab SE | Fully automated computerized powder XRD; X-ray tube: CuAngular range (2θ) : 2° to 150° | 2θ vs intensity plots / X-ray diffractograms; Quantitative analysis and other studies including phase identification, unit cell parameter determination, Particle size determination etc. |
3 | Scanning Electron Microscope with EDS | Jeol JSM / JSM-IT500LA | Magnification up to 3,00,000 X Resolution : 3nm Acc. Voltage up to 30kV Max. specimen size: 200mm Dia X 75mm height Fully computer controlled Carbon, Gold coating | Surface topographic / morphological studies of microstructures on bulk specimens of biological or other materials ; SEI, BEI images; image Analysis etc. |
4 | CD Spectrometer | Jasco/J-1500 | Xenon arc lamp source Temperature ramping (-400 to 1300C) and thermal denaturation for screening binding High speed scanning (10000 nm/min) | Identifying structural aspects of proteins and DNA. Determine how similar a wild type protein is to mutant or show the extent of denaturation with a change in temperature or chemical environment. Studies on chiral molecule etc. |
SOPHISTICATED ANALYTICAL INSTRUMENT FACILTY (SAIF)
KARNATAK UNIVERSITY, DHARWAD
Pavatenagar, Dharwad-580 003
E-mail : saifkud@gmail.com or usicofficekud@rediffmail.com
phone : 0836-2215295